Power_Plant_Induced_Draft_Fan_Fault_Prediction_using_Machine_Learning_Stacking_Ensemble.pdf (908.05 kB)
Download filePower Plant Induced-Draft Fan Fault Prediction using Machine Learning Stacking Ensemble
preprint
posted on 2022-11-02, 04:20 authored by Tlamelo EmmanuelTlamelo Emmanuel, Dimane Mpoeleng, Thabiso MaupongThe data used our analysis is from an ID fan which is part of a coal powered plant that produces a target output of 117W. The fan is placed at the outlet of the boiler. The fan runs at an air flow rate of 5365 Am3/min , with a density of 0.85 kg/m3, diameter of 2440 mm , with a total pressure of 505 mmAq and a speed of 989 rpm. The fan impeller is driven by a 650 kW electric induction motor (6600 V 50 Hz 3 Phase) with a speed of 1000 rpm.
Funding
Botswana International University of Science and Technology
History
Email Address of Submitting Author
tlamelo.emmanuel@studentmail.biust.ac.bwORCID of Submitting Author
0000-0002-6340-063XSubmitting Author's Institution
Botswana International University of Science and TechnologySubmitting Author's Country
- Botswana